Nominali srovė IN
45 A (Total current input)
Pastaba
EMC – Immunity for industrial areas
EMC interference emission for professional devices that are used in business and commercial areas as well as in small businesses
Environmental influences – Moisture and heat, constant
Environmental influences – Shocks
Environmental influences – Vibrations (sinusoidal)
Equipping power installations with electronic equipment
LABS release – in accordance with test specification VW PV 3.10.7:2005-0
When connecting the conductor, make sure that the CAPAROC modules are not pulled apart due to tensile force. Gaps must not be created between the modules.
Uždarosios grandinės srovė I0
typ. 46 mA (no load at 24 V)
Adresavimas
DHCP (default), BootP, static, ACD
Vardinė srovė I N
45 A (Total current input)
Nominali viršįtampio įtampa
Uždarosios grandinės srovė I 0
typ. 46 mA (no load at 24 V)
Galios išsklaidymas
< 4.5 W (at 40 A)
typ. 1.1 W (no load at 24 V)
Temperatūrinis galios sumažėjimas
20 A (Total current at 65 °C)
45 A (Total current at 60°C, in accordance with UL)
45 A (Total current at 60°C)
MTBF (IEC 61709, SN 29500)
3958056.77 h (at 40°C with 34.25% load)
7242508.37 h (at 25 °C with 21 % load)
764697.81 h (at 60°C with 100% load)
Išjungimas dėl per mažos įtampos
≤ 9.2 V DC (active)
≥ 10.2 V DC (inactive)
Apsauga nuo viršįtampio
≤ 29.5 V DC (inactive)
≥ 30.5 V DC (active)
Izoliacijos nuėmimo ilgis
Laido skerspjūvis, lankstus, su antgaliu, su plastiko mova
0.2 mm² ... 0.75 mm²
0.5 mm² ... 16 mm²
Laido skerspjūvis, lankstus, su antgaliu, be plastikinės movos
0.2 mm² ... 1.5 mm²
0.5 mm² ... 16 mm²
Laido skerspjūvio plotas (fiksuotas)
Maksimalus sistemos išplėtimas
≤ 16 (CAPAROC modules alignable)
Perdavimo fizika
Ethernet in RJ45 twisted pair
Prijungimas X1, žalia LED lemputė
Prijungimas X1, geltona LED
Prijungimas X2 geltona LED
Maitinimo (PWR) šviesos diodas žalias
3x flashing (Global programming lock deactivated)
lit (Supply voltage within the operating voltage range)
Maitinimo (PWR) LED raudonas
5x flashing (Factory reset command accepted)
lit (Supply voltage outside the operating voltage range)
Maitinimo (PWR) geltona šviesos diodė
3x flashing (Global programming lock activated)
lit (PWR button pressed)
NET LED išjungtas
off (No voltage present at the device or no IP address configured)
„NET“ žalia šviesos diodė
flashing (IP address available, no communication with the controller)
lit (Communication with the controller present)
NET raudona šviesos diodė
lit (Address Conflict Detection (ACD): “Duplicate IP.” Device has detected that its IP address is already in use in the network.)
NET LED raudona-žalia
flashing (Device initialization self-test)