Nominali srovė IN
1 / 2 / 3 / 4 A DC (Adjustable via rotary coding switches)
1 / 2 / 3 / 4 A DC (can be set, in RC mode via power module with communication interface)
4 A (per channel)
Pastaba
EMC – Emission for residential, business and commercial properties and small operations
EMC – Immunity for industrial areas
Environmental influences – Moisture and heat, constant
Environmental influences – Shocks
Environmental influences – Vibrations (sinusoidal)
Equipping power installations with electronic equipment
LABS release – in accordance with test specification VW PV 3.10.7:2005-0
When connecting the conductor, make sure that the CAPAROC modules are not pulled apart due to tensile force. Gaps must not be created between the modules.
Uždarosios grandinės srovė I0
typ. 25 mA (no load at 24 V)
Vardinė srovė I N
1 / 2 / 3 / 4 A DC (Adjustable via rotary coding switches)
1 / 2 / 3 / 4 A DC (can be set, in RC mode via power module with communication interface)
4 A (per channel)
Nominali srovė (iš anksto nustatyta)
Nominali viršįtampio įtampa
Įjungimo uždelsimas
50 ms (each channel preset by default)
can be adapted with CAPAROC PM IOL and CAPAROC PM PN power modules
Reikalingas atsarginis saugiklis
Only required if Imax of the power supply > the short-circuit switching capacity. Integrated failsafe element.
Trumpojo jungimo perjungimo galia
Aktyvi srovės ribojimo funkcija
typ. 1.5 x IN at IN = 4 A
typ. 2.0 x IN at IN ≤ 3 A
Uždarosios grandinės srovė I 0
typ. 25 mA (no load at 24 V)
Galios išsklaidymas
< 1.1 W (in nominal operation at 24 V and 4 A)
typ. 0.6 W (no load at 24 V)
Matavimo paklaida I
± 10 % (2 A ... 4 A)
± 20 % (1 A)
MTBF (IEC 61709, SN 29500)
11364927 h (at 25 °C with 21 % load)
5271554 h (at 40°C with 34.25% load)
640731 h (at 65°C with 100% load)
Apsauginis elementas
5 A DC (per output channel)
Kontaktų perjungimo tipas
without electrical isolation
Išjungimo laikas
≤ 400 ms (max. 450 ms for high starting currents)
5 s (for overload 1.1…1.7 x IN at IN < 4 A)
5 s (with overload 1.1…1.3 x IN at IN ≥ 4 A)
typ. 20 ms (for short circuit > 1,5 x IN)
Išjungimas dėl per mažos įtampos
≤ 8.5 V DC (active)
≥ 9.2 V DC (inactive)
Apsauga nuo viršįtampio
≤ 30.5 V DC (inactive)
≥ 32.5 V DC (active)
Maks. talpinė apkrova
≤ 60000 µF (Depending on the current setting and the short-circuit current available)
Izoliacijos nuėmimo ilgis
Lankstaus laidininko skerspjūvis
Laido skerspjūvio plotas (fiksuotas)
Laido skerspjūvis, lankstus, su antgaliu, su plastiko mova
Laido skerspjūvis, lankstus, su antgaliu, be plastikinės movos
Kanalo šviesos diodė išjungta
off (Channel switched off)
Kanalo LED geltona
lit (Channel switched on, channel load > 80% )
two flashes (Check the installation, no communication to power module)
Kanalo LED žalia
flashing (Channel switched on, coding switch position is not equal to set value)
lit (Channel switched on)
Kanalo raudona šviesos diodė
flashing (Channel switched off, ready to be switched back on, overload or short-circuit release)
lit (Channel switched off, over- or undervoltage active)
ON temporarily (Channel switched off, 5 s cool-down phase, overload or short-circuit release)
two flashes (Channel switched off, system total current limit exceeded)
Kanalo šviesos diodas raudonas-geltonas
flashing (Channel is overloaded and is switched off)
Kanalo LED raudona-žalia
flashing (Channel switched off, programming mode active, current adjustment after overload or short-circuit release)