CCCex pastaba
Use in potentially explosive areas is not permitted in China.
MTTF
2001 Years (SN 29500 standard, temperature 25°C, operating cycle 21%)
355 Years (SN 29500 standard, temperature 40°C, operating cycle 100%)
870 Years (SN 29500 standard, temperature 40°C, operating cycle 34.25%)
MTBF
179 Years (Telcordia standard, 40°C temperature, 34.25% operating cycle (5 days a week, 12 hours a day))
666 Years (Telcordia standard, 25°C temperature, 21% operating cycle (5 days a week, 8 hours a day))
Valdymas
SNMP v1/v2
Web-based management
Web-based management, SNMP, emergency exit with Telnet and serial
Palaikomos naršyklės
Netscape Communicator versions 4.5 and up or Internet Explorer versions 5.5 and up
Elektrinė izoliacija
VCC // Ethernet // Serial
Maksimali galios išsklaida nominaliomis sąlygomis
Bandymo įtampa duomenų sąsajoje/duomenų sąsajoje
1.5 kVrms (50 Hz, 1 min.)
Bandymo įtampos duomenų sąsaja / maitinimo šaltinis
1.5 kVrms
1.5 kVrms (50 Hz, 1 min.)
Maitinimo įtampos diapazonas
19.2 V AC/DC ... 28.8 V AC/DC (via pluggable COMBICON screw terminal block)
22.8 V DC ... 25.2 V DC (as an alternative or redundant, via backplane bus contact and system current supply)
Nominali maitinimo įtampa
24 V AC/DC ±20 % (via pluggable COMBICON screw terminal block)
24 V DC ±5 % (as an alternative or redundant, via backplane bus contact and system current supply)
Būsenos ir diagnostikos indikatoriai
LEDs: UL (logic voltage), TD + RD (data activity serial), FD (full duplex), 100 (100 Mbps mode), Link (Ethernet), Activity (Ethernet), ERR (error)
Viengyslis laidininkas/jungimo taškas, nelankstus
Viengyslis/jungimo taškas, lankstus
Izoliacijos nuėmimo ilgis
Prisukimo sukimo momentas
Rekomenduojamas
1 kV
1 kV (5 kHz)
Ethernet
Serijinio perdavimo greitis
0.3; 0.6; 1.2; 2.4; 4.8; 7.2; 9.6; 19.2; 38.4; 57.6; 115.2; 187.5; 230.4 kbps
10/100 Mbps, auto negotiation
Prijungimo būdas
D-SUB 9 plug
Plug-in/screw connection via COMBICON
RJ45 jack, shielded
Perduodamo signalo ilgis
≤ 100 m (shielded twisted pair)
≤ 1200 m
15 m
Pagalbiniai protokolai
ARP, DHCP, BOOTP, SNMP, RIP, RARP, HTTP, TFTP, ICMP
Išvadų paskirstymas
DTE/DCE switchover via web-based management
Failo formatas/kodavimas
UART/NRZ: 7/8 Bit Data, 1/2 Bit Stopp, None/Even/Odd Parity
Duomenų srauto valdymas / protokolai
Automatic control
Software handshake, Xon/Xoff or hardware handshake RTS/CTS
Uždarymo rezistorius
180 Ω
390 Ω
390 Ω (configurable)
Laisvasis kritimas pagal IEC 60068-2-32
Atsparumas vibracijai pagal EN 60068-2-6/IEC 60068-2-6
Operation: 5g, 10...150 Hz, 2.5 h, in XYZ direction
Atsparumas smūgiams pagal EN 60068-2-27/IEC 60068-2-27
Operation: 15g, 11 ms period, half-sine shock pulse
Storage/transport: 30g, 11 ms period, half-sine shock pulse
Aplinkos temperatūra (darbinė)
-20 °C ... 60 °C (in acc. with UL)
-25 °C ... 60 °C
Aplinkos temperatūra (sandėliavimas/transportavimas)
Aukštis virš jūros lygio
≤ 5000 m (For restrictions, see the manufacturer's declaration for altitude operation)
Leidžiama drėgmė (eksploatacijos metu)
10 % ... 95 % (non-condensing)
Leidžiama drėgmė (sandėliavimas/transportavimas)
5 % ... 95 % (non-condensing)
Sertifikatas
CE-compliant
KCC-REI-PCK-FL2313478
PxCIF11ATEX2313478X
Identifikacija
508 Listed
Class I, Div. 2, Groups A, B, C, D
Class I, Zone 2, AEx nA IIC T5
Class I, Zone 2, Ex nA IIC T5 Gc X
ISA-S71.04-1985 G3 Harsh Group A
II 3 G Ex ec IIC T4 Gc
Pastaba
Please follow the special installation instructions in the documentation!
Elektromagnetinis suderinamumas
Conformance with EMC Directive 2014/30/EU