CCCex pastaba
Use in potentially explosive areas is not permitted in China.
MTTF
125 Years (SN 29500 standard, temperature 40°C, operating cycle 100%)
308 Years (SN 29500 standard, temperature 40°C, operating cycle 34.25%)
711 Years (SN 29500 standard, temperature 25°C, operating cycle 21%)
Diagnostinės funkcijos
Logbook
Topological overview, event and path diagnostics
Pagrindinės funkcijos
Ethernet extenders in accordance with ITU-T G.991.2
Valdymas
Plug and Play, diagnostics via PSI-CONF software or web-based management (only with managed Ethernet extenders)
Redundancija
Proprietary SHDSL redundancy protocol (Managed and unmanaged Ethernet extenders)
Elektrinė izoliacija
VCC // Ethernet // DSL (A) // DSL (B) // FE
Maksimali galios išsklaida nominaliomis sąlygomis
Bandymo įtampos duomenų sąsaja / maitinimo šaltinis
1.5 kV AC (50 Hz, 1 min.)
500 V AC (In accordance with EN/IEC 60079-7)
Maitinimo įtampos diapazonas
Nominali maitinimo įtampa
24 V DC ±5 % (as an alternative or redundant, via backplane bus contact and system current supply)
5 V DC (configuration only, via mini-USB type B)
Maks. srovės suvartojimas
≤ 2 A (For operation in a joining station, via the DIN rail connector)
Būsenos ir diagnostikos indikatoriai
LEDs: US (supply voltage), ACT/LINK (Ethernet data traffic), ERR (errors)
2x LINK / 2x STAT (DSL data traffic port A and port B), DIAG (diagnostic messages)
Išėjimo signalo įtampa
18 V DC ... 30 V DC (depending on the operating voltage)
Išeinantis srovės signalas
≤ 150 mA (Short-circuit-proof)
Išėjimų veikimas
Deactivated for device supply via DIN rail connector
Prijungimo būdas
1 port 10/100Base-T(X), auto negotiation
2 x 2-pos. COMBICON plug-in screw terminal blocks
COMBICON plug-in screw terminal block
Mini-USB type B, 5-pos.
RJ45 jack, shielded
Prisukimo sukimo momentas
Rekomenduojamas
± 1 kV (asymmetrical, shielded Ethernet cable)
± 1 kV (asymmetrical: line to ground, unshielded SHDSL cable)
± 2 kV
Ethernet
Serijinio perdavimo greitis
10/100 Mbps, auto negotiation
2-wire operation: 32 kbps ... 15.3 Mbps
4-wire operation: 64 kbps ... 30 Mbps
Perduodamo signalo ilgis
< 100 m (shielded twisted pair)
< 20 km (Depending on data rate and cable cross section)
< 5 m (only for configuration and diagnostics)
Palaikomi protokolai
Protocol-transparent for TCP/IP, IPv4, and IPv6
Viengyslis laidininkas/jungimo taškas, nelankstus
Viengyslis/jungimo taškas, lankstus
Maks. lanksčiojo laidininko skerspjūvio plotas pagal AWG
Min. AWG laidininko skerspjūvis, lankstus
Viengyslis laidas/jungimo taškas, standus, AWG maks.
Viengyslis/gnybtas, standus, AWG min.
Izoliacijos nuėmimo ilgis
Atsparumas vibracijai pagal EN 60068-2-6/IEC 60068-2-6
Operation: 5g, 10...150 Hz, 2.5 h, in XYZ direction
Atsparumas smūgiams pagal EN 60068-2-27/IEC 60068-2-27
Aplinkos temperatūra (darbinė)
-20 °C ... 45 °C (aligned without spacing and supply of other modules via the device, 1.5 A)
-20 °C ... 50 °C (Mounted in rows with zero spacing)
-20 °C ... 55 °C (Mounted in rows with zero spacing and low power dissipation of aligned modules)
-20 °C ... 60 °C (Freestanding (40 mm spacing to the right and left), no supply of other modules via the device)
Aplinkos temperatūra (sandėliavimas/transportavimas)
Aukštis virš jūros lygio
≤ 5000 m (For restrictions, see the manufacturer's declaration for altitude operation)
Leidžiama drėgmė (eksploatacijos metu)
10 % ... 95 % (non-condensing)
Leidžiama drėgmė (sandėliavimas/transportavimas)
10 % ... 95 % (non-condensing)