CCCex pastaba
Use in potentially explosive areas is not permitted in China.
Spalva (korpusas)
white aluminium (RAL 9006)
Prijungimo būdas
RJ45
Screw connection
SFP
Pastaba apie jungimo būdą
Auto negotiation and autocrossing
Perdavimo greitis
10/100 Mbps
100/1000 Mbps (full duplex)
Perdavimo fizika
Depending on the SFP module
Ethernet in RJ45 twisted pair
Perduodamo signalo ilgis
100 m
up to 80 km (Depending on the fiber/SFP module used)
Signaliniai šviesos diodai
Data receive, link status
Kanalų skaičius
2 (SFP ports)
8 (RJ45 ports)
MTTF
49.9 Years (MIL-HDBK-217F standard, temperature 25°C, operating cycle 100%)
Apsaugos klasė
III (VDE 0106, IEC 60536)
Pagrindinės funkcijos
Store and forward switch, Extended Ring and IEEE redundancy, Multicast control, IGMP snooping, trunking, Port and Tagging VLANs, Port and IEEE 802.1x security, SNMP V3 and Https security, SNTP, web customization, user accounts
Signalinio kontakto valdymo įtampa
Signalo kontakto valdymo srovė
Redundancija
ERR (Extended ring redundancy)
Būsenos ir diagnostikos indikatoriai
Vietinė diagnostika
LNK/ACT Link status/data transmission Green LED
US1, US2 Supply voltage Green LED
Maksimali galios išsklaida nominaliomis sąlygomis
Bandymo sekcija
Supply voltage/functional ground 500 V 1 min
Maitinimo įtampos diapazonas
Likutinis pulsavimas
3.6 VPP (within the permitted voltage range)
Laido skerspjūvis, standus
Lankstaus laidininko skerspjūvis
Izoliacijos nuėmimo ilgis
Aplinkos temperatūra (darbinė)
Aplinkos temperatūra (sandėliavimas/transportavimas)
Leidžiama drėgmė (eksploatacijos metu)
5 % ... 95 % (non-condensing)
Leidžiama drėgmė (sandėliavimas/transportavimas)
5 % ... 95 % (non-condensing)
Oro slėgis (darbinis)
57 kPa ... 108 kPa (up to 4850 m above mean sea level)
Oro slėgis (sandėliavimas/transportavimas)
57 kPa ... 108 kPa (up to 4850 m above mean sea level)
ATEX
II 3 G Ex nA nC IIC T4 Gc
ES tipo tyrimo sertifikatas