Tipinis paleidimo laikas esant Us
1 s (when controlled via A1; applicative control via A1/A2 is not permitted)
Vardinė valdymo grandinės maitinimo įtampa US
Pritaikymas
Emergency stop
Light grid
Magnetic switch
Safety door
Safety shut-off mats
Two-hand control
Vardinė valdymo maitinimo srovė IS
typ. 45 mA (When sensor circuit and start circuit are controlled externally)
typ. 55 mA (When sensor circuit and start circuit are controlled internally)
Energijos suvartojimas esant US
Relės tipas
Electromechanical relay with force-guided contacts in accordance with IEC/EN 61810-3
Pervoltos kategorija
III (Between logic and enabling current paths)
Tipinis reakcijos laikas
< 100 ms (Automatic/manual start)
< 500 ms (Safety shut-off mat operation)
Tipinis paleidimo laikas, kai U < sub > s < /sub >
1 s (when controlled via A1; applicative control via A1/A2 is not permitted)
Tipinis išjungimo laikas
< 25 ms (on demand via the sensor circuit)
< 25 ms (When requested via A1; applicative deactivation via A1/A2 is not permitted)
< 85 ms (Safety shut-off mat operation)
Atkūrimo laikas
> 100 ms (Availability time after activating the sensor circuit during manual start)
> 500 ms (Availability time after activating the sensor circuits during manual start in safety shut-off mat operation)
500 ms (following demand of the safety function)
Paleidimo impulso trukmė
min. 500 ms (manual start)
Maksimali galios išsklaida nominaliomis sąlygomis
21.65 W (At US = 30 V, IL² = 100 A²)
Nominalus veikimo režimas
Nominali izoliacijos įtampa
Nominali impulsinė įtampa / izoliacija
See data sheet, section “Insulation coordination”.
Vardinė valdymo grandinės maitinimo įtampa U S
Nominali valdymo maitinimo srovė I S
typ. 45 mA (When sensor circuit and start circuit are controlled externally)
typ. 55 mA (When sensor circuit and start circuit are controlled internally)
Energijos suvartojimas esant U S
Paleidimo srovė
< 45 mA (typ. with US, Δt <50 µs)
< 45 mA (typ. with US)
max. 6 A
min. 10 mA
typ. 35 A (Δt = 25 µs at Us)
Filtravimo laikas
< 1 ms (High test pulses at >100 ms test pulse rate possible)
1 ms (logic)
max. 3 ms (Test pulse width of low test pulses)
min. 50 ms (Test pulse rate for low test pulse)
Apsauginė grandinė
Reverse polarity protection
Serial protection against polarity reversal
Suppressor diode
Varistor
Įėjimo aprašymas
IEC 61131-2 type 3
non-safety-related
safety-related
Įėjimo įtampos diapazonas „0“ signalui
Įėjimo įtampos diapazonas „1“ signalui
Įėjimo srovės diapazonas „0“ signalui
Atitiktis
∞ (2-channel wiring), 5 s (non-equivalent wiring), 0.5 s (two-hand control)
Maks. leistina bendra laidininko varža
Išėjimo aprašymas
2 NO contacts each in series, without delay, floating
non-safety-related
safety-related
Kontaktų perjungimo tipas
Perjungimo įtampa
max. 250 V AC/DC
min. 10 V
Ribojamas nuolatinis srovės stipris
Kv. Bendroji srovė
100 A2 (observe derating)
Mechaninis tarnavimo laikas
Išėjimo saugiklis
4 A gL/gG (for low-demand applications)
6 A gL/gG