MTTF
144 Years (SN 29500 standard, temperature 40°C, operating cycle 34.25%)
294 Years (SN 29500 standard, temperature 25°C, operating cycle 21%)
61 Years (SN 29500 standard, temperature 40°C, operating cycle 100%)
Pagrindinės funkcijos
Gigabit Ethernet extender in accordance with ITU G.9960
Valdymas
Plug and Play, diagnostics via LEDs, PoL switch on the device
Redundancija
Ring segment redundancy (All devices at a ring segment)
Šifravimo metodai
AES path encryption, Advanced Encryption Standard
Elektrinė izoliacija
VCC (US+GND) // Ethernet (PoE) // G.hn (without PoL) // FE
Bandymo įtampos duomenų sąsaja / maitinimo šaltinis
1.5 kV AC (50 Hz, 1 min.)
Maitinimo įtampos diapazonas
Nominali maitinimo įtampa
24 V DC (Without PoL)
48 V DC (With PoL)
Energijos suvartojimas
≤ 37.5 W (With PoL)
≤ 7.5 W (Without PoL)
Apsauginė grandinė
Overload protection, protection against polarity reversal; Internal device protection: 2x 5 AF, internal series diode
Prijungimo būdas
Push-in spring connection
RJ45 jack, shielded
Laido skerspjūvis, lankstus, su antgaliu, be plastikinės movos
Laido skerspjūvis, lankstus, su antgaliu, su plastiko mova
2 laidai su vienodu skerspjūviu, lankstūs, su TWIN antgaliais su plastikinėmis movomis
Viengyslis laidininkas/jungimo taškas, nelankstus
≥ 0.5 mm² (PoL cables in accordance with DIN VDE 0100, part 523)
0.2 mm² ... 2.5 mm²
Viengyslis/jungimo taškas, lankstus
≥ 0.5 mm² (PoL cables in accordance with DIN VDE 0100, part 523)
0.2 mm² ... 2.5 mm²
Lankstaus laidininko skerspjūvis [AWG]
Izoliacijos nuėmimo ilgis
Rekomenduojamas
± 1 kV (Ethernet signal / asymmetrical: shielded Ethernet cable)
± 1 kV (Telecommunication lines, symmetrical, unshielded, without primary protection)
± 2 kV (Ethernet signal / symmetrical: cable to cable, unshielded G.hn cable)
± 2.2 kV (Ethernet, G.hn)
± 4 kV (Ethernet signal / asymmetrical: cable to ground, unshielded G.hn cable)
± 4 kV (Telecommunication lines, symmetrical, unshielded, with primary protection)
Ethernet
Serijinio perdavimo greitis
Pastaba apie jungimo būdą
Autonegotiation
CAT6
Short-circuit-proof
Perduodamo signalo ilgis
< 100 m (shielded twisted pair)
≤ 1000 m (Depending on the quality of the data line)
Palaikomi protokolai
Protocol-transparent for TCP/IP, IPv4, and IPv6
Perdavimo greitis
≤ 1000 Mbps (Depending on the quality of the data line)
Maks. lanksčiojo laidininko skerspjūvio plotas pagal AWG
Min. AWG laidininko skerspjūvis, lankstus
Perdavimo būdas
QAM (quadrature amplitude modulation) carrier frequency method
Atsparumas vibracijai pagal EN 60068-2-6/IEC 60068-2-6
Atsparumas smūgiams pagal EN 60068-2-27/IEC 60068-2-27
Aplinkos temperatūra (darbinė)
-40 °C ... 50 °C (Free standing, PoE up to 30 W)
-40 °C ... 55 °C (Free standing, PoE up to 15 W)
-40 °C ... 60 °C (Free standing, without PoE)
Aplinkos temperatūra (sandėliavimas/transportavimas)
Leidžiama drėgmė (eksploatacijos metu)
10 % ... 95 % (non-condensing)
Leidžiama drėgmė (sandėliavimas/transportavimas)
10 % ... 95 % (non-condensing)
Identifikacija
ISA-S71.04-1985 G3 Harsh Group A