MTTF
151 Years (SN 29500 standard, temperature 40°C, operating cycle 34.25%)
324 Years (SN 29500 standard, temperature 25°C, operating cycle 21%)
62 Years (SN 29500 standard, temperature 40°C, operating cycle 100%)
Pagrindinės funkcijos
Gigabit Ethernet extender in accordance with ITU G.9960
Valdymas
Plug and Play, diagnostics via LEDs, PoL switch on the device
Redundancija
Ring segment redundancy (All devices at a ring segment)
Šifravimo metodai
AES path encryption, Advanced Encryption Standard
Elektrinė izoliacija
VCC (US+GND) // Ethernet (PoE) // G.hn (without PoL) // FE
Bandymo įtampos duomenų sąsaja / maitinimo šaltinis
1.5 kV AC (50 Hz, 1 min.)
Maitinimo įtampos diapazonas
Nominali maitinimo įtampa
24 V DC (Without PoL)
48 V DC (With PoL)
Energijos suvartojimas
≤ 37.5 W (With PoL)
≤ 7.5 W (Without PoL)
Apsauginė grandinė
Overload protection, protection against polarity reversal; Internal device protection: 2x 5 AF, internal series diode
Prijungimo būdas
BNC female connector for coaxial cables, 75 Ω
Push-in spring connection
RJ45 jack, shielded
Laido skerspjūvis, lankstus, su antgaliu, be plastikinės movos
Laido skerspjūvis, lankstus, su antgaliu, su plastiko mova
2 laidai su vienodu skerspjūviu, lankstūs, su TWIN antgaliais su plastikinėmis movomis
Viengyslis laidininkas/jungimo taškas, nelankstus
≥ 0.5 mm² (PoL cables in accordance with DIN VDE 0100, part 523)
0.2 mm² ... 2.5 mm²
Viengyslis/jungimo taškas, lankstus
≥ 0.5 mm² (PoL cables in accordance with DIN VDE 0100, part 523)
0.2 mm² ... 2.5 mm²
Lankstaus laidininko skerspjūvis [AWG]
Izoliacijos nuėmimo ilgis
Rekomenduojamas
± 1 kV (Ethernet signal / asymmetrical: shielded Ethernet cable)
± 1 kV (Telecommunication lines, symmetrical, unshielded, without primary protection)
± 2 kV (Ethernet signal / symmetrical: cable to cable, unshielded G.hn cable)
± 2.2 kV (Ethernet, G.hn)
± 4 kV (Ethernet signal / asymmetrical: cable to ground, unshielded G.hn cable)
± 4 kV (Telecommunication lines, symmetrical, unshielded, with primary protection)
Ethernet
Serijinio perdavimo greitis
Pastaba apie jungimo būdą
Autonegotiation
CAT6
Short-circuit-proof
Perduodamo signalo ilgis
< 100 m (shielded twisted pair)
≤ 1000 m (Depending on the quality of the data line)
Palaikomi protokolai
Protocol-transparent for TCP/IP, IPv4, and IPv6
Perdavimo greitis
≤ 1000 Mbps (Depending on the quality of the data line)
Perdavimo būdas
QAM (quadrature amplitude modulation) carrier frequency method
Atsparumas vibracijai pagal EN 60068-2-6/IEC 60068-2-6
Atsparumas smūgiams pagal EN 60068-2-27/IEC 60068-2-27
Aplinkos temperatūra (darbinė)
-40 °C ... 50 °C (Free standing, PoE up to 30 W)
-40 °C ... 55 °C (Free standing, PoE up to 15 W)
-40 °C ... 60 °C (Free standing, without PoE)
Aplinkos temperatūra (sandėliavimas/transportavimas)
Leidžiama drėgmė (eksploatacijos metu)
10 % ... 95 % (non-condensing)
Leidžiama drėgmė (sandėliavimas/transportavimas)
10 % ... 95 % (non-condensing)
Identifikacija
DNV
ISA-S71.04-1985 G3 Harsh Group A