Nominali srovė IN
1 / 2 / 3 / 4 / 5 / 6 / 7 / 8 / 9 / 10 A DC (adjustable per output channel)
max. 40 A (IN+)
max. 40 A (per terminal position when bridging additional devices via IN+)
Pastaba
Always connect the negative pole to terminal IN- to ensure the internal power supply. Return currents from the loads must not be fed back to the power supply via IN- of the circuit breaker.
EMC – Emission for residential, business and commercial properties and small operations
EMC – Immunity for industrial areas
Environmental influences – Moisture and heat, constant
Environmental influences – Shocks
Environmental influences – Vibrations (sinusoidal)
Equipping power installations with electronic equipment
Repeated hard short circuits can reduce the melting integral of the integrated backup fuse.
Uždarosios grandinės srovė I0
Tipas
DIN rail module, one-piece
Vardinė srovė I N
1 / 2 / 3 / 4 / 5 / 6 / 7 / 8 / 9 / 10 A DC (adjustable per output channel)
max. 40 A (IN+)
max. 40 A (per terminal position when bridging additional devices via IN+)
Nominali srovė (iš anksto nustatyta)
Nominali viršįtampio įtampa
Reikalingas atsarginis saugiklis
Only required if Imax of the power supply > the short-circuit switching capacity. Integrated failsafe element.
Trumpojo jungimo perjungimo galia
Dielektrinis stipris
max. 35 V DC (Load circuit)
Uždarosios grandinės srovė I 0
Galios išsklaidymas
< 9 W (Nominal operation)
typ. 0.6 W (No-load operation)
Modulio inicijavimo laikas
Laukimo laikas po kanalo išjungimo
5 s (at overload / short circuit)
Temperatūrinis galios sumažėjimas
24 A DC (at 60 °C)
28 A DC (at 54 °C)
32 A DC (at 47 °C)
36 A DC (at 41 °C)
40 A DC (at 35 °C)
MTBF (IEC 61709, SN 29500)
3067484 h (at 40°C with 34.25% load)
534188 h (at 35 °C with 100 % load)
8403361 h (at 25 °C with 21 % load)
Apsauginis elementas
15 A DC (per output channel)
Kontaktų perjungimo tipas
without electrical isolation
Išjungimo laikas
≤ 10 ms (for short circuit > 2.0 x IN)
1 s (1.2 ... 2.0 x IN)
Išjungimas dėl per mažos įtampos
≤ 17.8 V DC (active)
≥ 18.8 V DC (inactive)
Apsauga nuo viršįtampio
≤ 29.5 V DC (inactive)
≥ 30.5 V DC (active)
Maks. talpinė apkrova
45000 µF (Depending on the current setting and the short-circuit current available)
Įjungimo uždelsimas
0.1 s (per output channel)
Įėjimo įtampos diapazonas
7 V DC ... 30 V DC (Reset with falling edge)
Impulso trukmė
≥ 50 ms (High)
≥ 50 ms (Low)
Įtampa
< 5 V DC (Low state)
> 8 V DC (High state)
Izoliacijos nuėmimo ilgis
Laido skerspjūvio plotas (fiksuotas)
0.2 mm² ... 10 mm²
0.2 mm² ... 2.5 mm²
Laido skerspjūvis, lankstus, su antgaliu, su plastiko mova
0.25 mm² ... 1.5 mm²
0.25 mm² ... 4 mm²
Laido skerspjūvis, lankstus, su antgaliu, be plastikinės movos
0.25 mm² ... 2.5 mm²
0.25 mm² ... 6 mm²
Išeinamoji srovė
max. 0.04 A (Short-circuit-proof)
Lankstaus laidininko skerspjūvis
Kanalo šviesos diodė išjungta
off (Channel switched off)