Tipinis paleidimo laikas esant Us
< 200 ms (with Us when controlled via A1)
Vardinė valdymo grandinės maitinimo įtampa US
19.2 V DC ... 30 V DC
24 V DC -20 % / +25 % (provide external protection)
Vardinė valdymo maitinimo srovė IS
Energijos suvartojimas esant US
Pritaikymas
Emergency stop
Light grid
Safety door
Safety shut-off mats
Tipinis reakcijos laikas
< 175 ms (manual, monitored start)
< 200 ms (automatic start)
Tipinis paleidimo laikas, kai U < sub > s < /sub >
< 200 ms (with Us when controlled via A1)
Reakcijos laikas
< 10 ms (Take the extension of the response time into consideration if you switch several devices in sequence.)
Atkūrimo laikas
100 ms (Availability time after activating the sensor circuit during manual start)
250 ms (following demand of the safety function)
Paleidimo impulso trukmė
min. 250 ms (manual start)
Maksimali galios išsklaida nominaliomis sąlygomis
3.1 W (UB = 30 V , IL1 = IL2 = 2.4 A)
Nominalus veikimo režimas
Nominali izoliacijos įtampa
Nominali impulsinė įtampa / izoliacija
See data sheet, section “Insulation coordination”.
Vardinė valdymo grandinės maitinimo įtampa U S
19.2 V DC ... 30 V DC
24 V DC -20 % / +25 % (provide external protection)
Nominali valdymo maitinimo srovė I S
Energijos suvartojimas esant U S
Paleidimo srovė
< 10 mA (typ. with US at S10/S12, Δt = 500 µs)
< 10 mA (typ. with US, Δt < 100 ms)
< 10 mA (Δt = 500 µs)
< 5 A (Δt = 200 µs at Us)
> -5 mA (typ. with US at S22, Δt = 500 µs)
max. 4.8 A (Δt = 10 ms)
Filtravimo laikas
1 ms (For the logic. At A1 in the event of voltage dips at Us )
Deactivate the switch-on pulses for safety applications.
Does not apply for S22
max. 1.5 ms (Test pulse width of low test pulses)
Test pulse rate = 5 x Test pulse width
Apsauginė grandinė
Freewheeling circuit for inductive loads
Parallel protection against polarity reversal; Suppressor diode (Provide external fuse protection, see safety notes. Fuse type: 5 AT)
Suppressor diode
Įėjimo aprašymas
IEC 61131-2 type 3
IEC 61131-2 type 3 (S10, S12) PNP (S22)
non-safety-related
NPN
safety-related
safety-related sensor inputs
Įėjimo įtampos diapazonas „0“ signalui
0 V DC ... 5 V DC
0 V DC ... 5 V DC (S10, S12)
S22 open
Įėjimo įtampos diapazonas „1“ signalui
0 V ... 0 V (S22)
11 V DC ... 30 V DC
11 V DC ... 30 V DC (S10, S12)
19.2 V DC ... 30 V DC
Įėjimo srovės diapazonas „0“ signalui
0 mA ... 2 mA
0 mA ... 2 mA (S10, S12)
Maks. leistina bendra laidininko varža
Srovės suvartojimas
-4 mA (S22)
< 5 mA (typ. with US at S35)
< 7 mA (typ. with US at S34)
4 mA (S10, S12)
7 mA
Išėjimo aprašymas
non-safety-related
PNP
PNP, IEC 61131-2 Type 2
Safety-related digital outputs
Nuotėkio srovė
max. 1 mA (in the safe state)
Maks. talpinė apkrova
max. 10 µF (2.4 A load)
max. 4.7 µF (1 A load)
Įtampos, susidarančios nutraukus grandinę, ribojimas
Perjungimo dažnis
1 Hz (Resistive, inductive, capacitive)
Išjungimo metu išėjimo įtampa
< 5 V DC (in the safe state)
Bandymo impulsai
< 1 ms (Test pulse width of low test pulses)