Typ. starting time with Us
< 100 ms (with Us / when controlled via A1)
Rated control circuit supply voltage US
Rated control supply current IS
Application
Emergency stop
Safety door
Mechanical service life
107 cycles
10x 106 cycles
Relay type
Electromechanical relay with force-guided contacts in accordance with IEC/EN 61810-3
Typical response time
< 100 ms (For Us autostart)
< 100 ms (with Us manual start)
Typ. starting time with Us
< 100 ms (with Us / when controlled via A1)
Typical release time
< 10 ms (At Us on demand via sensor circuit)
< 100 ms (At Us/on demand via A1)
Recovery time
< 1 s (following demand of the safety function)
Maximum power dissipation for nominal condition
16 W (US = 26.4 V, IL² = 72 A²,PTotal max = 1.6 W + 14.4 W)
Rated surge voltage/insulation
Rated control circuit supply voltage US
Rated control supply current IS
Inrush current
< 3.5 A (typ. with US, Δt = 2 ms)
< 6 mA (typ. with US, Δt = 65 ms)
80 mA (typ. with US, Δt = 150 ms)
max. (Δt = 100 ms)
max. 6 A
min. 10 mA
Filter time
1 ms (Test pulse width of low test pulses)
1 s (Test pulse rate for low test pulse)
2 ms (in the event of voltage dips at Us)
No brightness test pulses / high test pulses permitted.
No test pulses permitted
Protective circuit
Serial protection against polarity reversal; Suppressor diode
Suppressor diode
Description of the input
non-safety-related
safety-related
Input voltage range "0" signal
Input voltage range "1" signal
Input current range "0" signal
Max. permissible overall conductor resistance
Current consumption
0 mA (typ. with US)
typ. 50 mA (with US at S11)
typ. 52 mA (with US supplied externally)
Output description
2 N/C contacts parallel, non-safety-related, floating
2 N/O contacts in series, safety-related, floating
Contact switching type
1 signaling current path
4 enabling current paths
Switching voltage
max. 250 V AC/DC
min. 10 V
min. 5 V
Switching capacity
1.5 A (AC15)
3 A (AC15)
5 A (DC13)
Limiting continuous current
Sq. Total current
36 A2 (observe derating)
72 A2 (observe derating)
Output fuse
10 A gL/gG (High demand)
4 A gL/gG (Low demand)
6 A gL/gG
Conductor cross-section rigid