Rated control circuit supply voltage US
Rated control supply current IS
125 mA AC (at US)
60 mA DC (at US)
Application
Safety door
Two-hand control
Mechanical service life
10x 106 cycles
approx. 107 cycles
Relay type
Electromechanical relay with force-guided contacts in accordance with IEC/EN 61810-3
Overvoltage category
II, III (See the section “Insulation coordination”)
Typical release time
20 ms (on demand via A1)
90 ms (on demand via the sensor circuit)
Restart time
< 1 s (Boot time, after switching on the supply voltage)
Recovery time
< 500 ms (following demand of the safety function)
Maximum power dissipation for nominal condition
16.6 W (US = 26.4 V, IL² = 72 A², PTotal max = 2.2 W + 14.4 W)
Rated surge voltage/insulation
6 kV / Safe isolation, increased insulation
Rated control circuit supply voltage US
Rated control supply current IS
125 mA AC (at US)
60 mA DC (at US)
Protective circuit
Serial protection against polarity reversal
Suppressor diode
Surge protection
Description of the input
non-safety-related
safety-related sensor inputs
Input voltage range "0" signal
Input voltage range "1" signal
Input current range "0" signal
Max. permissible overall conductor resistance
Output description
2 N/C contacts parallel, non-safety-related, floating
2 N/O contacts each in series, safety-related, floating
Contact switching type
1 signaling current path
2 enabling current paths
Switching voltage
max. 250 V AC
max. 250 V AC/DC
min. 15 V AC/DC
Inrush current
max. 5 A
max. 6 A
min. 10 mA
Switching capacity
1.5 A (AC15)
2 A (DC13)
5 A (AC15)
6 A (DC13)
Limiting continuous current
5 A
6 A (observe derating)
Sq. Total current
25 A2
72 A2 (observe derating)
Output fuse
10 A gL/gG
4 A gL/gG (for low-demand applications)
5 A gL/gG
Conductor cross-section rigid