Input voltage range in reference to UN
Typical input current at UN
Date of last data management
Maximum power dissipation for nominal condition
Test voltage (Winding/contact)
2.5 kVrms (50 Hz, 1 min., winding/contact)
Test voltage (Contact/contact)
2.5 kVrms (50 Hz, 1 min., contact/contact)
Input voltage range
102 V AC ... 132 V AC (20 °C)
Input voltage range in reference to UN
Typical input current at UN
Typical release time range
Operating voltage display
Maximum switching voltage
Minimum switching voltage
Limiting continuous current
Maximum inrush current
50 A (20 ms, N/O contacts)
Interrupting rating (ohmic load) max.
108 W (60 V DC)
124 W (48 V DC)
216 W (24 V DC)
2250 VA (250 V AC)
4000 VA (440 V AC)
52 W (110 V DC)
70 W (220 V DC)
Motor load according to UL 508
1/2 HP, 240 V AC (single-phase AC motor)
1/2 HP, 240 V AC (three-phase induction motor)
1/3 HP, 120 V AC (single-phase AC motor)
Utilization category CB Scheme (IEC 60947-5-1)
AC15, 1.5 A/240 V (N/O contact)
DC13, 2 A/240 V (N/O contact)
Conductor cross-section rigid
0.14 mm² ... 1.5 mm²
0.14 mm² ... 2.5 mm²
Conductor cross-section flexible
0.14 mm² ... 1 mm² (Ferrule with plastic sleeve, two conductors on double terminal block)
0.14 mm² ... 1.5 mm²
0.14 mm² ... 1.5 mm² (Ferrule with plastic sleeve)
0.14 mm² ... 2.5 mm²
0.14 mm² ... 2.5 mm² (Ferrule with plastic sleeve)
Conductor cross-section AWG
26 ... 14 (flexible)
26 ... 14 (solid)
26 ... 16 (flexible)
26 ... 16 (solid)