Typ. starting time with Us
< 70 ms (with Us when controlled via A1)
Rated control circuit supply voltage US
19.2 V DC ... 30 V DC
24 V DC -20 % / +25 %
Rated control supply current IS
Application
Ex
High demand
Low demand
Safe switch off
Relay type
Electromechanical relay with force-guided contacts in accordance with IEC/EN 61810-3
Typ. starting time with Us
< 70 ms (with Us when controlled via A1)
Typical release time
< 10 ms (when controlled via A1)
Maximum power dissipation for nominal condition
Rated surge voltage/insulation
Rated control circuit supply voltage US
19.2 V DC ... 30 V DC
24 V DC -20 % / +25 %
Rated control supply current IS
Inrush current
max. 100 mA
max. 6 A
min. 1 mA
min. 3 mA
typ. 120 mA (Δt <10 ms at Us)
Filter time
> 1 s (at A1-A2; high test pulse rate)
> 30 ms (at A1-A2; low test pulse rate)
max. 2 ms (at A1-A2 in the event of voltage dips at Us)
max. 2 ms (at A1-A2; high test pulse width)
max. 2 ms (at A1-A2; low test pulse width)
Output description
2 N/O contacts in series, without delay, floating
Contact switching type
1 confirmation current path
1 enabling current path
Switching voltage
max. 250 V AC/DC
max. 30 V DC
min. 12 V AC/DC
min. 5 V DC
Switching capacity
4 A (24 V (DC13))
5 A (250 V (AC15))
Limiting continuous current
100 mA
4 A (Low demand)
6 A (High demand)
Output fuse
150 mA Fast-blow
4 A gL/gG (for low-demand applications)
6 A gL/gG
Conductor cross-section rigid
Conductor cross-section flexible
Conductor cross-section AWG
Operating voltage display