Rated control circuit supply voltage US
Rated control supply current IS
Set comprises
1397653 PSR-ME40-4NO-2NC-24DC-SC-SET35
Mechanical service life
10x 106 cycles
approx. 107 cycles
Relay type
Electromechanical relay with force-guided contacts in accordance with IEC/EN 61810-3
Typical response time
typ. 40 ms (For Us autostart)
Maximum power dissipation for nominal condition
17 W (US = 26.4 V, IL² = 72 A², PTotal max = 2.6 W + 14.4 W)
Rated surge voltage/insulation
See data sheet, section “Insulation coordination”.
Rated control circuit supply voltage US
Rated control supply current IS
Inrush current
< 2.5 A (typ. with US, Δt = 1 ms)
max. 1 A
max. 6 A
min. 10 mA
Filter time
1 ms (Test pulse width of low test pulses)
1 s (Test pulse rate for low test pulse)
5 ms (in the event of voltage dips at Us)
No brightness test pulses / high test pulses permitted.
Input voltage range "0" signal
Input voltage range "1" signal
Input current range "0" signal
Max. permissible overall conductor resistance
Output description
2 N/C contacts parallel, non-safety-related, floating
2 N/O contacts each in series, safety-related, floating
Diagnostic contact, 2 NC in series, floating
Contact switching type
2 N/C contacts in series
4 enabling current paths
Switching voltage
max. 250 V AC/DC
min. 10 V AC/DC
Switching capacity
1 A (AC15)
1 A (DC13)
5 A (AC15)
6 A (DC13)
Limiting continuous current
1 A
1 A (observe derating)
6 A (Observe derating and load limit curve)
Sq. Total current
1 A2
1 A2 (observe derating)
72 A2 (observe derating)
Output fuse
1 A (gL/gG)
1 A gL/gG
10 A gL/gG
4 A gL/gG (for low-demand applications)
Conductor cross-section rigid